This range of switches have been designed to provide a rapid means of disconnecting batteries or other power supplies in the event of serious electrical faults. The switch is a manually operated device with a simple over-centre spring mechanism which provides a "snap action" for both opening and closing of the main contacts. All types are capable of safely rupturing full load battery currents in the event of an emergency.
Please note: Part numbers are for identification purposes only and do not indicate source of supply.

manual disconnect switch

ED125 Series Manual Disconnect Switches

Available as a standard (see picture) or locking version, 'L' denotes a lockable variant. For these versions a key is necessary for the knob to be moved from the "Off" position to the "On" position. Once in the "On" position, the key can be removed. Thereafter, the knob may be depressed to the "Off" position where it will automatically lock and remain locked until the key is used again to unlock it. Denoted by 'A', a double circuit normally open, normally closed microswitch auxiliary contact can be fitted and magnetic blowouts 'B', can also be fitted.

pdf iconClick here to view data sheet

ED250L Manual Disconnect Switch

ED250 Series Manual Disconnect Switches

Available as a standard or locking version (see picture), 'L' denotes a lockable variant. For these versions a key is necessary for the knob to be moved from the "Off" position to the "On" position. Once in the "On" position, the key can be removed. Thereafter, the knob may be depressed to the "Off" position where it will automatically lock and remain locked until the key is used again to unlock it. Denoted by 'A', a double circuit normally open, normally closed microswitch auxiliary contact can be fitted and magnetic blowouts 'B', can also be fitted.

pdf iconClick here to view data sheet

ED252 Manual Disconnect Switch

ED252 Series Manual Disconnect Switches

Available as a standard or locking version, 'L' denotes a lockable variant. For these versions a key is necessary for the knob to be moved from the "Off" position to the "On" position. Once in the "On" position, the key can be removed. Thereafter, the knob may be depressed to the "Off" position where it will automatically lock and remain locked until the key is used again to unlock it. Denoted by 'A', a double circuit normally open, normally closed microswitch auxiliary contact can be fitted (see picture) and magnetic blowouts 'B', can also be fitted.

pdf iconClick here to view data sheet

SD150 Combination Line and Quick Disconnect Switch

SD150 Series Combination Line and Quick Disconnect Switches

The SD150 switches combine the dual function of a manual disconnect and coil operated line contactor.
The operation of the switch is such that with the operating knob depressed i.e. in the "off" position, no electrical functions can take place. However, if the knob is in the "On" position, the option of energising the coil and thus closing the main contacts becomes available. The coil energisation can be carried out either through the vehicle keyswitch or as a result of a signal from the vehicle electronic controller. When used as an emergency battery disconnect switch, manually depressing the operating knob will override the energised coil such that the main contact and the auxiliary contact (where fitted) will open until such time as the knob is again moved to the "on" position.
Available as a standard (see picture) or locking version, 'L' denotes a lockable variant. For these versions a key is necessary for the knob to be moved from the "Off" position to the "On" position. Once in the "On" position, the key can be removed. Thereafter, the knob may be depressed to the "Off" position where it will automatically lock and remain locked until the key is used again to unlock it. Denoted by 'A', a double circuit normally open, normally closed microswitch auxiliary contact can be fitted and magnetic blowouts 'B', can also be fitted.

pdf iconClick here to view data sheet

SD250 Combination Line and Quick Disconnect Switch

SD250 Series Combination Line and Quick Disconnect Switches

The SD250 switches combine the dual function of a manual disconnect and coil operated line contactor.
The operation of the switch is such that with the operating knob depressed i.e. in the "off" position, no electrical functions can take place. However, if the knob is in the "On" position, the option of energising the coil and thus closing the main contacts becomes available. The coil energisation can be carried out either through the vehicle keyswitch or as a result of a signal from the vehicle electronic controller. When used as an emergency battery disconnect switch, manually depressing the operating knob will override the energised coil such that the main contact and the auxiliary contact (where fitted) will open until such time as the knob is again moved to the "on" position.
Available as a standard (see picture) or locking version, 'L' denotes a lockable variant. For these versions a key is necessary for the knob to be moved from the "Off" position to the "On" position. Once in the "On" position, the key can be removed. Thereafter, the knob may be depressed to the "Off" position where it will automatically lock and remain locked until the key is used again to unlock it. Denoted by 'A', a double circuit normally open, normally closed microswitch auxiliary contact can be fitted and magnetic blowouts 'B', can also be fitted.

pdf iconClick here to view data sheet

we don't just sell parts, we sell solutions

Elcon Europe Ltd • Oaktree Workshops • Oaktree Cottage • Milley Lane • Hare Hatch • Berkshire • RG10 9TL
Tel: +44 (0) 118 940 1444 • Fax: +44 (0) 118 940 1555 • email: sales@elcon.co.uk • www.elcon.co.uk

Site Map Site designed and maintained by Kayak Design Ltd
elcon email map